SQ3140/SQ3200/SQ3300 Generator

Brand

Kubota

Category

AgricultureConstructionDiesel GeneratorsDiesel GeneratorsSQ SeriesSQ Series

Series

Agriculture Construction Diesel Generators Diesel Generators SQ Series SQ Series

Model

  • SQ3140B
  • SQ3200B
  • SQ3300B

SQ3140/SQ3200/SQ3300 Generator

SQ3140/SQ3200/SQ3300 Generator

The Kubota SQ3140 is a premium compact three phase four pole diesel generator with a capacity of 14kVA at 1500RPM, the Kubota SQ-3200B-AU-B is super quiet with a capacity of 20kVA at 1500RPM and the SQ-3300B-AU-B diesel generator comes with 30kVA at 1500RPM capacity. These diesel generators are fully sound attenuated for super quiet operation. There’s no need to worry about engine fuel leakages, as both the SQ-3200B and SQ-3300B are fully bunded.

SQ3140/SQ3200/SQ3300 Generator

Specifications

GeneralSQ3140BSQ3200BSQ3300B

Fuel Type

Diesel Diesel Diesel

Phase

Three Three Three

Fuel Tank Capacity

72 l100 l142 l

Operating Hours @Full Load

24.8 hours25 hours24 hours

Starting System

Electric Electric Electric

Weight

780 kg915 kg1135 kg

Sound Levels @7m

61 dBA63 dBA64 dBA

Dimensions

1725 x 795 x 1095 mm1725 x 795 x 1180 mm1935 x 860 x 1310 mm
EngineSQ3140BSQ3200BSQ3300B

Engine Model

D1703-EBG V2203-EBG V3300-EBG

Engine Type

Vetical Water Cooled Vertical Water Cooled Vertical Water Cooled

Displacement

1647 cc1647 cc3318 cc

No of Cylinders

3 4 4

Bore & Stroke

87 x 92.4 mm87 x 92.4 mm98 x 110 mm

Rated Output

13.6 kW18.4 kW26.8 kw

RPM

1500 rpm1500 rpm1500 rpm
AlternatorSQ3140BSQ3200BSQ3300B

Type

Revolving Field Revolving Field Revolving Field

Max Output

15.4 kVA22 kVA33 kVA

Rated Output

14 kVA20 kVA30 kVA

Voltage

240/415 240/415 240/415

Frequently

50 Hz50 Hz50 Hz

Current

19.5 Amps27.8 Amps41.7 Amps

Power Factor

0.8 0.8 0.8

Poles

4 4 4

Voltage Regulation

AVR AVR AVR

Product Features

Engines

The Kubota SQ-3140B-AU-B is a premium compact three-phase four pole diesel generator with a capacity of 14kVA at 1500RPM and is available to work under a single phase 240 voltage and run a current (A) of 12.5 amps or a 3 phase 415 voltage and a run a current of 19.5 amps per phase. Powered by Kubota’s D1703 fuel efficient, water cooled diesel engine.

The Kubota SQ-3200B-AU-B is a premium compact three-phase four pole diesel generator with a capacity of 20kVA at 1500RPM and is available to work under a single phase 240 voltage and run a current (A) of 18.1 amps or a 3 phase 415 voltage and a run a current of 27.8 amps per phase. Powered by Kubota’s renowned V2203 water cooled diesel engine.

The Kubota SQ-3300B-AU-B is a premium compact three-phase four pole diesel generator with a capacity of 30kVA at 1500RPM and is available to work under a single phase 240 voltage and run a current (A) of 27.1 amps or a 3 phase 415 voltage and a run a current of 41.7 amps per phase. Powered by Kubota’s extra reliable V3300 water cooled diesel engine.

Kubota diesel engines incorporate a TVCS combustion system which improve air/fuel mixture, resulting in cleaner emissions. All models are available with automatic shutdown of the engine if abnormal conditions are detected.

Components

Brushless, self-exciting type alternator delivers reliable, high-quality power. Centre lifting lugs and fork lift slots ensure easy transportation. Single sided access for quick inspection and easy maintenance. All rotating parts enclosed in a sturdy lockable enclosure.

Runtimes

The SQ-3140B-AU-B diesel generator has a running range time of 24.5 hours at three quarter load, while the Kubota SQ-3200B-AU-B diesel generator delivers a run range time of 25 hours at three quarter load. The SQ-3300B-AU-B diesel generator has a running range time of 24 hours at three quarter load.

Solar applications

Fully bunded for your peace of mind in case of engine failure or fuel leaks, the Kubota SQ-3140, SQ-3200 and SQ-3300 are factory fitted with digital controller and 2-wire auto start model for solar applications. Power when you need it.

Safety

The Residual Current Device will be factory fitted and this will offer a high level of personal protection to the operator from electrical shock and provide high levels of protection from potential electrical fires. The factory fitted circuit breakers offer protection against suddenly large overloads of electrical flow and large power loads potentially destroying electrical equipment. The circuit breakers offer increased safety.

Base mounted fuel tank

The SQ Series is equipped with a large capacity bottom mounted fuel tank to prevent fuel spills inside the enclosure (Bunded 110%). The locking fuel door is placed to avoid damage and simplify refuelling

Control panel

Features – Emergency stop button, waterproof enclosure. Standard with manual key start and hard wire connection to output circuit breaker. Standard with Digital Control Panel- DSE4520. Optional weatherproof outlets available.

Receptacles

Four switches and four receptacles (IP66) with two additional spaces. Located below the switches (within the skid rail) are two tow points to aide in handling.

Receive a Quick Quote

OPEN HOURS

Service/Spare Parts:

Hallam

44 Wedgewood Rd, Hallam VIC 3803

Monday-Friday: 7:30am – 5:00pm

Currently closed on Saturdays until further notice

Epping

11 Legacy Rd, Epping VIC 3076

Monday-Friday: 7:30am – 5:00pm

Currently closed on Saturdays until further notice

Sales/Admin:

Hallam

44 Wedgewood Rd, Hallam VIC 3803

Monday-Friday: 8:30am – 5:00pm

Epping

11 Legacy Rd, Epping VIC 3076

Monday-Friday: 8:30am – 5:00pm

Call Us